Part Number Hot Search : 
MC74HC B431LBK3 45984 P4840 C18F44 AMC71 307C1545 36766
Product Description
Full Text Search
 

To Download ABTWF150C0 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 power entry modules without line filter 6145 https://www.schurter.com /pg05 connectors iec appliance inlet c14 with circuit breaker ta45 approvals and compliances c14 70 c description - panel mount : screw-on mounting from front side - 2 functions : appliance inlet protection class i , circuit breaker type ta45 2-pole - quick connect terminals 6.3 x 0.8 mm characteristics - all single elements are already wired - unwired versions available on request - circuit breaker non-illuminated or illuminated - suitable for use in equipment according to iec/ul 60950 references alternative: version with line filter 5145 we recommend for new applications the new type df11 weblinks pdf datasheet, html-datasheet, general product information, distributor- stock-check, accessories, detailed request for product, microsite newly available variants corresponding to v-lock mating cordset. the connector is equipped with a notch intended for use with the latching cordset. the cord latching system prevents against accidental removal of the cordset. technical data ratings iec 10 a / 250 vac; 50 hz ratings ul/csa 15 a / 250 vac; 60 hz dielectric strength > 1.5 kvac between l/n-pe (1 min/50 hz) allowable operation tempe - rature -10 c to 55 c ip-protection from front side ip 40 acc. to iec 60529 insulation cover suitable for appliances with protection class i acc. to iec 61140 terminal quick connect terminals 6.3 x 0.8 mm panel thickness s screw: max 6 mm mounting screw torque max 0.5 nm material: housing thermoplastic, black, ul 94v-0 appliance inlet/-outlet c14 acc. to iec 60320-1, ul 498, csa c22.2 no. 42 (for cold conditions) pin-temperature 70 c, 10 a, protection class i circuit breakers acc. iec/en 60934, ul 1077, csa 22.2 no. 235 2-pole rocker switch, illuminated or non- illuminated. optional with undervoltage- or remote trip release short circuit capacity icn: at in < 3a/240vac : 10 x in at in 3a/240vac : 300a approvals and compliances detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in details about approvals approvals the approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. approval reference type: 6145 approval logo certificates certification body description vde approvals vde vde certificate number: 40040061 ul approvals ul ul file number: e96454
2 power entry modules without line filter 6145 https://www.schurter.com /pg05 connectors product standards product standards that are referenced organization design standard description designed according to iec 60320-1 appliance couplers for household and similar general purposes designed according to iec 61058-1 switches for appliances. part 1. general requirements designed according to ul 498 standard for attachment plugs and receptacles designed according to csa c22.2 no. 42 general use receptacles, attachment plugs, and similar wiring devices application standards application standards where the product can be used organization design standard description designed for applications acc. iec/ul 60950 iec 60950-1 includes the basic requirements for the safety of information technologyequipment. compliances the product complies with following guide lines identification details initiator description ce declaration of conformity schurter ag the ce marking declares that the product complies with the applicable requirements laid down in the harmonisation of community legislation on its affixing in accordance with eu regulation 765/2008. rohs schurter ag eu directive rohs 2011/65/eu china rohs schurter ag the law sj / t 11363-2006 (china rohs) has been in force since 1 march 2007. it is similar to the eu directive rohs. reach schurter ag on 1 june 2007, regulation (ec) no 1907/2006 on the registration, evaluation, authorization and restriction of chemicals 1 (abbreviated as "reach") entered into force. dimensions [mm] 43.1 36 2 detail a 1 a 13.9 6.3x0.8mm 6.3x0.8mm 67.5 24.2 91.5 ? 3.3 ? 6.1 80 m3 / ? 3.6 72 +0.10 0 80 0.1 r3 -0.5 0 29 -0.2 0 * --- version ta45 with undervoltage release
3 power entry modules without line filter 6145 https://www.schurter.com /pg05 connectors diagrams 1) 2) l' p 1 n' p 2 n l pe pe' 1) line 2) load
4 power entry modules without line filter 6145 https://www.schurter.com /pg05 connectors abt w f 150 c0 colours switch fr ont rocker w black white ? b black black ? 6 black ? orange transp. f embossed / relief h printed / bedruckt white / weiss k printed / bedruckt black / schwarz l printed / bedruckt white / weiss surface illustration colour of print rocker legend l o on off on off l o m printed black p printed white r printed black surface illustration colour of print rated curr ent cir cuit br eaker of equipment without r elease: code c0 undervoltage r elease remote trip r elease ue za code rated voltage u n ? ? ? ? ? ? ? ? ? ? ? ? 2 3 4 240 v ac 230 v ac 120 v ac l o o i o i position of the r ocker legend e.g f i n code 0,1 j01 0,2 j02 0,3 j03 0,4 j04 0,5 j05 0,6 j06 0,7 j07 0,8 j08 0,9 j09 1,0 j10 1,1 j11 1,2 j12 i n code 1,3 j13 1,4 j14 1,5 j15 1,6 j16 1,7 j17 1,8 j18 1,9 j19 2,0 j20 2,1 j21 2,2 j22 2,3 j23 2,5 j25 i n code 2,8 j28 3,0 030 3,5 035 4,0 040 4,5 045 5,0 050 6,0 060 6,5 065 7,0 070 7,5 075 8,0 080 9,0 090 i n code 10,0 100 11,0 110 12,0 120 13,0 130 14,0 140 15,0 150 20,0 200 t able 1 selection for type t a45 or der example ? cir cuit br eaker of equipment ? 2-pole, r ocker actuated ? quick connect terminal other types on r equest w ithout illumination w ith illumination 220?240 v 110?120 v diagram thermal overload pr otection 1-pole 2-pole abt abd a12 a32 a14 a34 p2 p1 6 3 43 p2 p1 } p2 p1 u< p2 p1 b u< p2 p1 b a u< p2 p1 c
5 power entry modules without line filter 6145 https://www.schurter.com /pg05 connectors t echnical data (continued) cir cuit br eaker ef fect of ambient temperatur e 1) the unit is calibrated for an ambient temperatu re of +23 c. to deter mine the rated curr ent for a lower or higher ambient tempera- tur e, use a corr ection factor fr om the table below . * ambient temperatur e [c] corr ection factor ?10 0,89 ? 5 0,91 0 0,92 +23 1,00 +30 1,03 +40 1,08 +55 1,16 or der code t a45 (2-pole rocker -switch without accessories) configuration code (example) * te mperature must be measur ed at the re ar of the br eaker next to the terminals after equipment operating temperatur e has been reached. 1) example rated curr ent at +23 c 6,0 a ambient temperatur e +40 c corr ection factor 1,08 chosen rated curr ent at + 40 c ambient temperatur e 6 a x 1,08 = 6,5 a t ype t ripping characteristics i n < 3 a t ripping characteristics i n > _ 3? < _ 15 a 10?000 60 2000 1000 500 200 100 50 20 10 5 2 1 0, 5 0, 3 0, 2 0, 1 [ sec ] [ min ] 10 5 1 30 20 1,05 multiple of rated curr ent [ x i n ] 10 8 5 4 3 2 1,32 tr ipping time t ype ta 45 rated curr ent i n < 3 a 1-pole pr otected 2- pole pr otected ambient temp. +23 c 10?000 60 2?000 1?00 0 500 200 100 50 20 10 5 2 1 0,5 0,3 0,2 0,1 [ sec ] [ min ] 10 5 1 30 20 1,05 [ x i n ] 10 8 5 4 3 2 1,32 t ype ta 45 rated curr ent i > 3... < 15 a 1-pole pr otected 2- pole pr otected ambient temp. +23 c multiple of rated curr ent t ripping time n te rminal pe 1 quick-connect terminal 6.3x0.8 mm te rminal n 1 quick-connect terminals 6.3x0.8mm, without connection to t a45 4 connection to ta 45 non insulated te rminal l 1 quick-connect terminals 6.3x0.8mm, without connection to t a45 4 connection to ta 45 non insulated see table 1 6145 - ABTWF150C0 - 000 - 111 - 00 packaging unit 20 pcs accessories description assorted covers rear cover 0859.0074
6 power entry modules without line filter 6145 https://www.schurter.com /pg05 connectors mating outlets/connectors category / description appliance outlet overview complete iec appliance outlet f, screw-on mounting, front side, solder terminal 4787 iec appliance outlet f, snap-in mounting, front side, solder or quick-connect terminal 4788 iec appliance outlet f or h, screw-on mounting, front side, solder, pcb or quick-connect terminal 5091 appliance outlet further types to 6145 connector overview complete 4782 mounting: power cord, 3 x 1 mm2 / 3 x 18 awg, cable, connector: iec c13 4782 4022 mounting: power supply cord, 3 x 1.5 mm2, screw clamps, connector: iec c13 4022 4785 mounting: power cord, 3 x 1 mm2 / 3 x 18 awg, cable, connector: iec c13 4785 4300-06 mounting: power cord, 3 x 1 mm2 / 3 x 18 awg, cable, connector: iec c13 4300-06 4012 mounting: power supply cord, 3 x 1.5 mm2, screw clamps, connector: iec c13 4012 connector further types to 6145 ... mating outlets/connectors shuttered power cord overview complete power cord with iec connector c17, v-lock, straight vac17ks power cord further types to 6145 the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments. information furnished is believed to be accurate and reliable. however, users should independently evaluate the suitability and test each product selected for their own applications. 01.12.2017


▲Up To Search▲   

 
Price & Availability of ABTWF150C0

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X